| Specification | Detail |
|---|---|
| Unit type | Recessed floor panel with airflow and cable openings |
| Frame | Aluminium |
| Lid | Hinged, flip-open |
| Air openings | Slotted grille |
| Cable opening | Black bristle brush seal |
| Mounting | Set into a raised access floor panel cut-out |
| Position | Flush with the finished floor surface |
| Air duty | Set by the room's air strategy, whether supply from the plenum or return through it |
| Opening layout | Air grille and cable slot share the one frame aperture |
| Range | Supplied as part of the raised floor accessories line |
These units are set into a panel cut-out, so the opening matters more than the tile around it. The frame holds the cut edge and keeps the panel rigid around the aperture, which is why the fit is decided by the size and position of the opening rather than by brand. Tell us which panel you are working with — steel, calcium sulphate, wood core and aluminium panels all cut differently — and we will match the frame to it.
One more site check is worth doing before cutting: the space below the opening has to clear the cables and any tray already running through the void. We are raised flooring manufacturers, so we can match the frame to the tile and support system going into the same floor.
As a raised access flooring supplier, we cover a complete system rather than single items: pedestals and stringers, antistatic PVC and HPL tiles, PVC skirting, panel lifters and cutting blades, air diffusers, brush grommets, flip outlet boxes and in-floor cooling units. Our structural components suit OA, steel, wood core, calcium sulphate and aluminium raised floors, with pedestal heights from 70 to 1500 mm. Specifications such as stringer size and thickness can be customised to your project, so contractors can source compatible components, installation tools and cooling accessories from one supplier for data center, computer room and commercial fit-outs.
They sit side by side in the same frame. The slotted section stays open for air, and the brush section handles the cables, so a cable running through the unit does not sit across the airflow path and does not block it. The two sections work independently, so adjusting one does not disturb the other.
The unit sits in a cut-out rather than on top of the floor, so the fit depends on the opening, not on the panel brand. Tell us the panel type and the aperture size. We are raised flooring manufacturers, so we can tell you how the frame will sit against the tile edge before the panel is cut.
Yes. The lid lifts on its hinge, so cables can be added or rerouted without lifting the panel out of the grid. The raised floor brush grommet then closes around the new cables, keeping the opening tidy and the void below covered.
The bristles are soft and flexible, so they bend around a cable rather than gripping it. They hold cables loosely and let a length be pulled through when it is needed. Feed cables in by hand and avoid dragging them hard across the frame edge.
Lift the lid and vacuum or brush out the grille slots and the bristles. Do not oil or paint the brush, because stiff bristles stop closing around cables. A damp cloth on the frame is enough, and a quick clean at each floor inspection keeps the unit working as it should.
The frame is recessed into the cut-out and holds the cut edge, so the tile keeps its shape around the opening. Position matters more: the opening should fall inside the panel grid and not over a pedestal or stringer. Check that against your layout before cutting.