• Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box
  • Flip type Outlet Box

Description




Product Overview

A flip-lid outlet box sits recessed in a raised access floor panel and turns one spot in the floor into a service point for power and network cables. Open the hinged lid and you reach the socket or data modules inside; close it and the lid folds back into the frame. The housing takes a removable module frame, so the same box can be built for power, built for data, or left blank for a fit-out that has not been decided yet. Commercial flooring suppliers normally keep the common layouts in their accessory range, because the box is chosen when the room layout is set rather than after the floor has gone down.

Key Features

  • Flip-up lid: a single hinged lid lifts clear of the frame and folds back down, so an unused position disappears into the floor instead of leaving an open socket on show.
  • One housing, several layouts: a flip type floor outlet box can be supplied with a power socket module, a data frame with keystone cut-outs, or an empty compartment that is ready for a later fit-out.
  • Hinge fixed to the frame: the lid pivots on the metal frame rather than the panel, so repeated opening and closing does not loosen the panel opening.
  • Metal enclosure: the housing, mounting plate and brackets hold the modules square inside the opening, even when the panel is lifted out and refitted for maintenance.
  • Flush when closed: the lid finishes level with the panel surface, so the floor line stays continuous in open-plan and technical rooms. Where an area takes trolley traffic or rolling loads, tell us when you order so we can confirm the right set for that position.

Specifications

Product typeRaised floor outlet box with flip-up lid
MountingRecessed into a raised access floor panel opening
HousingMetal enclosure with internal mounting plate
LidHinged flip lid, closes level with the floor surface
Interior optionsPower socket module, data keystone frame, or empty compartment
Cable entrySide cable flaps and knock-outs on the housing
Supplied fittingsMounting brackets and screws
FinishDark grey / black
MarkingCCC mark on the housing

Installation & Fitting

  1. Set the housing into the panel opening so the top edge finishes level with the panel, then check that the lid swings clear of the frame before fixing anything down.
  2. Pull the power and data cables through the floor void first, and bring them up through the side flaps or knock-outs on the side you planned.
  3. Fix the mounting plate and brackets, fit the module frame for that position, and tighten only after the cables are dressed so nothing is pinched under the plate.
  4. Leave a service loop long enough to lift the lid fully and to re-terminate a module later without dragging the cable back through the floor.
  5. Where boxes are set into panels before the floor is laid, raised access flooring contractors usually have the opening cut in the panel workshop, which keeps every opening identical across a large room.

Where It's Used

Raised floor cable management is mostly about putting a connection where the work happens, and this box is the piece that does it. In open-plan offices it sits under workstation clusters and meeting tables, so desk power and network drops come up through the floor instead of trailing across it. Computer rooms and data halls use it at rack rows, KVM positions and build areas, where an engineer needs a socket or a patch point without lifting a whole tile. Monitoring and control rooms put it at the operator desk, and factory and laboratory fit-outs use it at benches where equipment needs a local connection rather than a wall socket run across the floor.

Scale & Supply Capability

As a raised access flooring supplier, we cover a complete system rather than single items: pedestals and stringers, antistatic PVC and HPL tiles, PVC skirting, panel lifters and cutting blades, air diffusers, brush grommets, flip outlet boxes and in-floor cooling units. Our structural components suit OA, steel, wood core, calcium sulphate and aluminium raised floors, with pedestal heights from 70 to 1500 mm. Specifications such as stringer size and thickness can be customised to your project, so contractors can source compatible components, installation tools and cooling accessories from one supplier for data center, computer room and commercial fit-outs.

FAQ

Q1. What is a raised floor outlet box used for?

It gives you a service point inside the floor rather than in the wall: power sockets for desks, monitors or test equipment, and data keystones for network or patch connections. Set into a panel, it keeps the cables in the void below and only the module you actually need shows at floor level. Offices, computer rooms and control rooms use it wherever equipment moves and the floor services have to stay tidy.

Q2. Can I have a flip type floor outlet box built for power only, data only, or both?

Yes. The same housing takes a power socket module, a data frame with keystone cut-outs, or a blank plate, so one room can be mixed according to what each position needs. Tell us the layout position by position when you order, since it is the module frame inside the box that changes, not the lid or the housing.

Q3. Will the box fit my existing raised floor panels?

It is made to sit in an opening in a raised access floor panel, so the housing has to match the panel you are using. Send us the panel type, panel thickness and the opening you plan to cut, and we will confirm the right housing before any cutting starts. Raised access flooring contractors usually check this against the panel drawing first, which avoids openings that end up too tight or too loose.

Q4. How do cables enter and leave the box?

Cables come up from the floor void through the side flaps or the knock-outs in the housing, and any entry you do not use stays closed, which keeps the box clean during construction. For raised floor cable management it is worth deciding which side the cables arrive from before the panel is cut, because it changes how the service loop is dressed inside the housing.

Q5. Can a box be fitted into a floor that is already installed?

Yes. The box is set into a single panel, so an installed floor can be converted by lifting that panel, cutting the opening and refitting it with the housing. It is quicker and neater to agree the opening before the floor is laid, because the panel can then be prepared in the workshop; if the floor is already down, work from the panel drawing so the opening matches the module layout you need.

Q6. What comes with each box?

Each box is supplied as a housing with its hinged flip lid, an internal mounting plate, brackets and screws. The socket module, keystone data frame or blank plate is selected as part of the layout you order. If you want spare module frames for later changes to a room, mention it when you order and we will confirm what can be supplied.